Dosimetry
Responsible: Javier Vijande Asenjo
One of the main concerns regarding the treatment of the patient affected by a tumor lesion is to obtain an accurate deposition of the absorbed dose, both in the lesion, in order to maximize the beneficial effect of the treatment, and in the nearby healthy organs, to minimize potential complications. In order to determine precisely said prescribed absorbed dose to the oncological lesion in the treatment planning phase, it is necessary to use models of radiation transport through the patient which involve very complex calculations and long calculation times. In clinical practice, regardless of the type of radiation to be used, effective analytical models are used that solve the radiation transport equation in a reasonable time. The price to pay is a loss in the accuracy of the calculation. The method currently considered the gold standard for this type of calculation is the Monte Carlo method. Its main advantage consists in providing an exact solution within the statistical uncertainty inherent to said method. The disadvantage, to this day, is the excessive calculation time that it entails, a fact that limits its use in clinical practice, being mainly relegated to pre- and post-treatment verifications. It is therefore essential to continue developing tools and techniques that allow this method to be transferred to a clinical environment, this being the main objective of this line of research.
This line of research is fortunate to have the collaboration of some of the main research groups in the field of Monte Carlo simulations. We currently collaborate with the groups of Shirin Enger, Luc Beaulieu, Asa Carlsson, Frank Verhaegen, Rowan M. Thomson, Rafael Miró, Frank-Andre Siebert and Mark Rivard. Likewise, we have the support of two of the main companies in the sector, Varian and Elekta, which participate in this line of research by facilitating the use of several of their calculation and planning systems.
The research group has access to a large number of intensive calculation systems, both its own (the Dresden calculation cluster) and the calculation facilities of the University of Valencia (Lluís Vives) and the Institute of Corpuscular Physics.
Publications:
- Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398. P Andreo et al 2020 Phys. Med. Biol. 65 095011.
- Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams. V. Giménez-Alventosa, V. Giménez, F. Ballester, J. Vijande and P. Andreo 2020 Phys. Med. Biol. 65 205005.
- Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya® unit: a Monte Carlo study. C. Valdes-Cortez et al 2020 Phys. Med. Biol. 65 245026.
- A Monte Carlo-based dosimetric characterization of Esteya®, an electronic surface brachytherapy unit. C. Valdes-Cortez, Y. Niatsetski, J. Perez-Calatayud, F. Ballester, J. Vijande 2019 Med. Phys. 46 356-369.
- Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125I prostate brachytherapy. F. Hueso-González, F. Ballester, J. Perez-Calatayud, F.-A Siebert. 2017 Siebert Brachytherapy 16 616-623