Protontherapy
Responsible: Enrique Nácher y José Perez-Calatayud
Proton therapy is a technique that uses proton beams instead of X-rays as ionising radiation. It has a far higher selectivity than conventional radiotherapy, what makes it ideal for the treatment of localised tumours in highly sensitive areas: brain, spinal cord… Proton therapy, with more than 150,000 patients treated worldwide and new centres under construction in Europe, is experiencing an exponential growth.
It is important to highlight here that the Hospital Universitario y Politécnico la Fe has been chosen for the implementation of the first proton therapy center in the Valencian Community. The time scale necessary for the implementation of this treatment system (2025) will probably mean that it would not be available during the development of this research project, but that does not prevent us to establish as one of the main long-term objectives of this project to implementat onsite any application develop within this project. This will allow the Hospital Universitario y Politécnico la Fe in particular, and the Valencian health system in general, to benefit from our results.
The application of proton therapy is not exempt of difficulties. The precision in the determination of the distal position of the distribution of dosage is crucial for complete irradiation of the tumour and to restrict the dose to organs at risk. This is why a real-time monitoring of the therapy is highly desirable.
In this context, we have built a proton-scanner device, within the framework of the PRONTO-CM project (ref. B2017/BMD-3888), that is a proof-of-concept detector for proton tomography. However, proton-range verification during treatment is out of the scope of the PRONTO-CM project. This is why we consider the limitations of the PRONTO-CM project as the starting point for this one.
Here we plan to test a novel method to verify the proton range during treatment using a novel redundant method. On one side, the secondary neutrons and gamma rays produced by the proton beam in the patient can be detected by a LaCl3 scintillation detector placed along the longitudinal axis of the beam. The counting rate measured will depend on the solid angle covered by this detector around the source of emission, therefore the position of the Bragg peak. On the other side, we plan to make use of an active neutron-proton converter (plastic scintillator) placed transversal to the beam axis. Behind the converter we will placed position sensitive silicon detectors to determine the trajectories of the resulting protons, which will allow us to reconstruct an image of the source emission, therefore the Bragg peak.
Collaborators in this research line: Universidad Complutense de Madrid and Instituto de Estructura de la Materia (CSIC), Madrid
Infraestructures: we count on the proton scanner developed within the PRONTO project and we plan to test our methodes at CMAM (Madrid), CNA (Sevilla) and/or IFJ-CCB (Krakow, Poland). In the future we plan to integrate the resulting prototype into the protontherapy facility at La Fe Hospital.
Publications:
- Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators. J. A. Briz et al 2022 IEEE Transactions on Nuclear Science 69 696-702.